Turn chilly floors into your home’s most efficient heat source with Warmup electric underfloor heating – featuring custom systems, all backed by expert Australian support and a comprehensive product guarantee.
From our Australian warehouse
Warranty
Before and after install
Warmup’s electric underfloor heating delivers radiant, uniform heat across your entire floor; eliminating the inconsistent temperatures, noise, dry air, and airborne dust associated with ducted vents or wall-mounted split systems. Designed for every major Australian subfloor type, the range includes loose wire heating for tiled bathrooms and ensuites, protective foil heating for timber floors, and inslab heating elements for concrete foundations; each engineered for long-term, reliable performance.
Perfectly suited to the Australian climate, these systems efficiently counteract cold winter mornings across Victoria, New South Wales, and South Australia, with easy zone control or complete shutdown in summer. Paired with intelligent digital thermostats, each floor zone operates according to your household routine for highly efficient electrical power use.
All systems are compatible with standard Australian 230V electrical mains and require installation by a licensed electrical contractor. Warmup’s local engineering desk offers complimentary floor plan optimisation, thermal load design, and technical support for projects ranging from single ensuite specifications to expansive multi-room builds with varying floor finishes.

Warmup inscreed heating incorporates electric cables straight into a screed layer — offering radiant heat under tiles, polished concrete, timber, laminate, or carpet in new constructions and extensions. This is the most favoured specification among architects and builders across Australia. Read more
The inslab heating cable is designed for installation within concrete slabs, perfect for new builds and additions. It provides soft, constant background heat, making it ideal for areas used for extended durations. It is an affordable option for newly poured foundations and ground slab residential constructions, installed prior to the concrete pour over the steel reinforcement mesh against the approved fixing position, cover depth and pour procedure. Read more
Undercarpet heating warms the the floor surface where you need it. Warmup’s undercarpet heaters are individually controlled, giving you a cost-effective heating system. These wafer-thin heating mats are placed between the carpet and underlay, and are available in multiple sizes to fit any space. This radiant heating system minimizes dusty air and drafts, rendering it a sensible option for sustaining a healthier indoor atmosphere. Read more
Our foil heaters provide uniform heat distribution and include a flexible core wire that can support approved floor-build-up, point-loading and permanent-furniture restrictions when properly installed. The internal wire cores withstand pressure while maintaining structural integrity. Together with smart floor temperature sensors, the system avoids excessive heat, maintaining the floor temperature within safe limits set by the manufacturer. Read more
Backed by more than 30+ years of global engineering, research, and technical optimisation, Warmup brings invisible, luxurious, and maintenance-free comfort straight to your living spaces.
Warmup has assisted thousands of homeowners, builders, and renovators across Australia and New Zealand in specifying, supplying, and installing electric underfloor heating across every room type and floor finish. Whether the project involves tiling a single bathroom or heating an entire new home from the slab up, Warmup’s technical team will design a system that performs — and support it with Australia’s most comprehensive underfloor heating guarantee.
A: In Australia, the price of underfloor heating depends on the type of system, the size of the room, the finish of the floor, and whether it’s included in a new construction or a renovation. Electric underfloor heating for a typical bathroom begins at a few hundred dollars, not including thermostat and installation expenses. Larger inslab or inscreed systems are charged per square meter and should be estimated based on particular floor designs.
A: Electric underfloor heating stays affordable when controlled by an intelligent WiFi thermostat. These systems employ sensors to heat only when needed, improving thermal efficiency when combined with high-quality insulation. Operating expenses are influenced by electricity rates, usage hours, and insulation standards; however, with efficient insulation and intelligent controls, expenses are comparable to other electric heating options while providing the benefit of uniform warmth.
A: Warmup produces tailored underfloor heating solutions that work with different Australian flooring types, such as ceramic, porcelain, marble, granite tiles, carpets, and engineered wood. Their high-conductivity cables and mats are compatible with most primary finishes, subject to compatibility checks. Warmup’s engineering team checks for compatibility before designing the system.
A: Absolutely. Renovations and floor replacements provide the perfect opportunity to introduce electric layouts. Laying thin undertile wire right within your flexible adhesive layer is the most popular retrofit path, adding no significant vertical bulk to your existing floor levels. For full-scale updates where a sand and cement bed is being replaced or floating boards are being pulled up, our inslab and foil pad systems fit into the renovation timeline seamlessly.
A: Yes, every electric system requires a dedicated Warmup thermostat to operate safely. The wall controller relies on an remote floor sensor to regulate temperatures, protect the element from overheating, and minimize your electrical power draw. Operating an underfloor element without an approved sensor controller compromises the system and increases running costs. We provide digital programmable, smart WiFi, and DUAL models control a floor zone and a heated towel rail from one unit.
A: Thermal response times depend on your chosen system depth and floor structure. An ultra-thin undertile wire can bring stone or ceramic surfaces to a beautiful temperature in roughly 20 to 40 minutes. Foundation inslab elements take longer to warm up initially due to the substantial concrete mass, but they hold and radiate that background heat far longer. Setting your smart timer to activate shortly before you wake up removes any manual waiting time.
A: Yes, our systems are explicitly approved for wet zones, including family bathrooms, ensuites, and laundry floors. The double-insulated wires feature robust protective earth screen and layer safely with approved waterproofing barriers before tiling begins. The elements satisfy Australian safety guidelines(AS/NZS 3000). In compliance with AS/NZS 3000 electrical regulations, the operating wall thermostat must be mounted safely outside designated splash zones.